• Civil Lab Mechanical Lab Engineering Lab Equipments
  • sales@didacticlabequipments.com

Thermal Conductivity Of Metal Rod

Thermal Conductivity Of Metal Rod

CAT NO: DIDACTICNLE-Export-064022

Thermal Conductivity Of Metal Rod Description and Tender Specification:

Thermal Conductivity Of Metal Rod.
Thermal Conductivity Of Metal Rod The experimental set up consists of metal bar, one end of which is heated by an electric heater while the other end of the bar projects inside the cooling water jacket. A cylindrical shell filled with insulating material surrounds the middle portion of the bar. The temperature of the bar is measured at different sections. Heat Input to the heater is Fiven through variac. By varying the heat input rates, data can be obtained. Water atconstant rate is circulated through the jacket and its flow rate and temperature rise is noted. EXPERIMENTATION: To plot the temperature distribution along the length of Bar. To determine the thermal conductivity of given bar at various temperatures. UTILITIES REQUIRED : Continuous Water supply @2LPM at 0.5 Bar Floor Drain. Electricity Supply : 1 Phase, 220 V AC, 2 Amp. Table for set-up support. Stop Watch TECHNICAL DETAILS : Metal Bar Material : Copper Length : 400 mm (approx.) Diameter : 25 mm Insulating shell Length : 250 mm Diameter : 200 mm Cooling Water Jacket Water Flow measurement : By Measuring cylinder Digital Voltmeter : 0-300 Volt. Variac : 0-230 V, 2 Amp. Digital Temp. Indicator : 0-199.90C, with multi-channel switch, Temperature Sensors : RTD PT-100 type. Instruction Manual : An ENGLISH instruction manual will be provided along with the Apparatus The whole setup is mounted on a powder coated base plate. 

Support