CAT NO: DIDACTICNLE-Export-037005
The
test is applicable to hot mix designs using bitumen and aggregates upto
a maximum size of 25mm. In this method,.
Bitumen-Asphalt Testing Lab equipment manufacturers,exporters and Bitumen-Asphalt Testing Lab suppliers the resistance to plastic
deformation of cylindrical specimen of bitumenous mixture is measured
when the same is loaded at periphery at 5 cm per min. This test
procedure is used in designing and evaluating bituminous paving mixes.
The test procedure is extensively used in routine test programmes for
paving jobs. There are two major features of the Marshall method of
designing mixes namely, a) Density – voids analysis b) Stability – flow
tests. The marshall stability of mix is defined as a maximum load
carried by a compacted specimen at a standard test temperature of 60ºC.
The flow value is deformation the marshall test specimen under goes
during the loading upto the maximum load, 0.25 mm units. In this test
and attempt is made to determine optimum binder content for the type of
aggregate mix and traffic intensity.
Salient Features
The apparatus consists of :
A
loading unit motorized, capacity 5000kgf with two telescopic pillars
and an adjustable cross head. Limit switches are fitted inside to
control upward or downward movement of the pillars. On-off reversing
switch and indicator lamps are on the front side while a hand wheel to
manually move the pillars is on the right. The load frame has fixed
speed of 5.08cm per minute. Operated on 230 Volts A.C.
1 No. Compaction pedal with specimen mould holder.
2 Nos. Compaction Rammers, 4.5kg weight and free fall 45.7cm.
1 No. Breaking head assembly with provision to fix flow meter.
3 Nos. Specimen mould 10.16cm I.D. x 7.6cm high with base plate and extension collar.
1 No. Kit for specimen extraction, consists of one each load transfer bar, steel ball, specimen extracting plate.
Accessories :
Integral type Proving Ring capacity 3000 kgs.
A dial gauge 0.01 x 25mm
Universal Water Bath S.S. with false bottom and pyramid shaped lid to accomodates 3 Nos. marshall specimen
Thermometer 0 - 250ºC x 1ºC.