CAT NO: DIDACTICNE4984
Laminar Flow Table.
[1] Floor standing apparatus demonstrates ideal flow, and Hele Shaw principles and is able to accept student made models. [2] Working section and end tanks made of glass reinforced plastic. [3] Working section dimensions 606mm x 892mm. [4] Lower glass plate incorporates 8 sinks/sources in cruciform pattern and viewing graticule. [5] A system of pipes, valves and manifolds enables any configuration of sinks and sources to be used. [6] Includes dye injection system, and adjustable knife edge weir for rapid, accurate adjustment of table flow. [7] Comprehensive instruction manual with illustrations. [8] Experimental capabilities: †Ideal flow around immersed bodies †cylinder, aerofoil, bluff body †Ideal flow in channels and at boundaries †convergent channel, divergent channel, 90 degree bend, sudden contraction, sudden enlargement, replacement of a streamline by a solid boundary †Ideal flow associated with sinks and sources †formation of Rankine half body, formation of a Rankine oval, circular streamlines from a doublet, superposition of sinks and sources †Use of streamlines to analyse twoâ€dimensional flow †Research †modelling twoâ€dimensional systems